| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and commissioning without enforcing a mandatory password change. Unauthenticated attackers can use these default credentials to gain administrative access to sensitive smart home configuration and control functions. |
| Default credentials set for local privileged user in Virtual Appliance. The following products are affected: Acronis Cyber Protect Cloud Agent (VMware) before build 36943, Acronis Cyber Protect 17 (VMware) before build 41186. |
| Tattile Smart+, Vega, and Basic device families firmware versions 1.181.5 and prior ship with default credentials that are not forced to be changed during installation or commissioning. An attacker who can reach the management interface can authenticate using the default credentials and gain administrative access, enabling unauthorized access to device configuration and data. |
| SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a default credentials vulnerability that allows remote attackers to obtain administrative access to the management interface. Attackers can authenticate using the hardcoded default credentials without password change enforcement to gain full administrative control of the device. |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges. |
| NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL.
This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed.
This issue has been fixed in version 0.57.0 |
| Legacy Vivotek Device firmware uses default credetials for the root and user login accounts. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| All the Toshiba printers share the same hardcoded root password. As for the affected products/models/versions, see the reference URL. |
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory.
For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.
Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared.
Newer firmware versions might be vulnerable as well. |
| BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or
series 5 prior to v9.0.166 use a default password that is guessable with
knowledge of the device information. The latest release fixes this
issue for new installations; users of old installations are encouraged
to change all default passwords. |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator. |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.
This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01. |
| ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. |